STANDARD HEAT PUMP CHECKLIST $ 79.95

• Confirm system operation and cycle through thermostat
• Measure supply and return air temperature
• Clean and level thermostat
• Compare voltage and amp. draw on all motors to rating
• Align blower belt
• Adjust belts for proper tension
• Clean indoor coil
• Clean outdoor coil
• Examine contactors and capacitors
• Test amp. on compressor and compare to rating
• Measure refrigeration pressures
• Test emergency heat
• Verify operation of reversing value
• Compare amperage draw on each heating element
• Remove “Squirrel” cage fan and clean
• Test door safety switch
• Test operation of high limit fan control
• Examine all wiring and electrical connections; repair cap tape loose wiring as necessary